TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualifi ed
service personnel.
All electronic components have 120 - 240 volt ac and low voltage dc potential on their terminals.
Shorting of terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be per-
manent. If an intermittent condition is encountered, the cause will likely be a switch contact or
a loose connection at a terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if sole-
noids are energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fi ttings are tightened or loosened.
This will help avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and iso-
lated.
This brewer is heated at all times. Keep away from combustibles.
WARNING
Exercise extreme caution when servicing electrical equipment.
Disconnect the brewer from the power source when servicing, except when electrical tests are
specifi ed.
Follow recommended service procedures.
Replace all protective shields or safety notices.
Screen Displayed
Possible Cause
Troubleshooting Procedures
1. Overfl ow cup is full of water. This
could be caused by boiling; see chart
on page 33. Also could be Refi ll Sen-
sitivity adjustment; see page 34.
Empty cup. Correct cause and
retry.
1. SMART FUNNEL
not fully inserted
into the funnel rails.
2. Not using a SMART FUNNEL,
and the FUNNEL DETECT function
is activated (on).
Position the funnel so that the sensor
is directly beneath the sensor coil on
the brewer.
Disable the FUNNEL DETECT func-
tion.
OVERFLOW CUP
FULL. EMPTY CUP
NO FUNNEL
PRESENT
35058.1 071205