SERVICE (cont.)
CONTACTOR ASSEMBLY (cont.)
Test Procedures :
Electronic Control (Brewers w/Recovery Booster)
1. Disconnect the brewer from the power source.
2. Disconnect the gray wire from the black wire on
the contactor coil and white /brown wire from the
remaining black wire on the contactor coil.
NOTE: ECA MODELS ONLY - Brewer must be at
operating temperature to perform step #3 or brew-
lock must be bypassed. To bypass brew-lock
disconnect white/orange and brown/black for right
timer or orange and red/black for left timer from
brew-lock of ECA and connect harness leads to-
gether.
3. Check the voltage across the gray wire and white/
brown with a voltmeter with both "ON/OFF" switches
in the "ON" position. Connect the brewer to the
power source and press both start switches. The
indication must be:
a.) 120 volts ac for three wire 120/208 volt mod-
els and three wire 120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
wiring diagrams and check the brewer wiring harness.
5. Disconnect the blue and red wires from the
contactor terminals. Check for continuity across
the terminals of the contactor by manually closing
the contacts. Continuity must not be present when
the contact is released.
If continuity is present as described, reconnect the
blue and red wires to the contactor terminals. Connect
one black lead from the contactor coil to the gray wire
and the white/brown wire to the remaining black lead
of the contactor coil. Reconnect brew-lock wires to
interlock of the ECA if necessary. The contactor is
operating properly.
If continuity is not present as described, replace the
contactor.
P778
BLK to BLK Lead from Thermostat
BLK to White Lead from the Three
Pole 120/208V or 120/240V
Terminal Block
BLK to Red Lead from the Two
Pole 200V or 240V Terminal
Block
RED T1 to Left Tank Heater
RED T1 to Right Tank Heater
BLK T2 to Left Tank Heater
BLK T2 to Right Tank Heater
BLK L2 to Terminal Block
(Black Insert)
RED L1 to Terminal Block
(Red Insert)
MECHANICAL THERMOSTAT W/RECOVERY BOOSTER
RED T1 to To Terminal Block
(Red Insert )
BLK to WHI/BRN to
Left Dispense Valve
BLK to GRY on
Relay
BLU L1 to Left Tank
Heater
ELECTRONIC CONTROL W/RECOVERY BOOSTER
Removal and Replacement:
1. Remove all wires from the contactor.
2. Remove the two #10-32 slotted head screw secur-
ing contactor to the inside of the hood.
3. Securely install the new contactor inside the hood.
4. Refer to the following illustration when reconnect-
ing the wires.
27124 050800