6. Gently remove the capillary bulb and grommet
from the tank.
7. Check the voltage across the black wires of the
control thermostat and the white insert on the
three pole 120/208V, 120/240V terminal blocks
and the red insert on two pole 200V, 240V terminal
blocks with a voltmeter when the control thermo-
stat is turned "ON" (fully clockwise). Connect the
brewer to the power source. The indication must
be:
a.) 120 volts ac for three wire 120/208 volt mod-
els and three wire 120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
Voltage must not be indicated across these
terminals when the thermostat is turned "OFF"
(fully counterclockwise).
8. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the capillary
tube into the tank to the line 7" above the bulb, the
control thermostat is operating properly.
If voltage is not present as described, replace the
thermostat.
Removal and Replacement:
1. Remove wires from the control thermostat.
2. Remove the thermostat capillary bulb by firmly
pulling-up on the capillary tube at the tank lid. This
will disengage the grommet from the tank lid.
3. Remove the #8-32 slotted head screw holding the
control thermostat to the component bracket.
4. Slide the grommet to the line 7" above the bulb on
the new capillary tube.
5. Insert the capillary bulb through the hole in the
tank lid and press the grommet firmly and evenly
so that the groove in the grommet fits into the tank
lid.
6. Carefully bend the capillary tube so that the tube
and bulb inside the tank are in the vertical position.
NOTE - The capillary tube must be clear of any electri-
cal termination and not kinked.
7. Using a #8-32 slotted head screw fasten the con-
trol thermostat to the component bracket.
8. Refer to the illustration below when reconnecting
the wires.
9. Adjust the control thermostat as required.
P974
Location:
The control thermostat is located inside the
lower left front of the brewer on the component
bracket.
1. Disconnect the brewer from the power source.
2. Locate the blue wire on the control thermostat.
3. Check the voltage across the blue wire on the
control thermostat and the white insert on three
pole 120/208V, 120/240V terminal block and the
red insert on two pole 200V, 240V terminal block
with a voltmeter. Connect the brewer to the power
source. The indication must be:
a.) 120 volts ac for three wire 120/208 volt mod-
els and three wire 120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
wiring diagrams and check the brewer wiring harness.
5. Locate the black wires from the control thermo-
stat.
Page view 17