MODEL CWT
SERVICE
This section provides procedures for testing
and replacing various major components used in
this brewer should service become necessary. Refer
to Troubleshooting for assistance in determining the
cause of any problem.
WARNING - Inspection, testing, and repair of electri-
cal equipment should be performed only by qualified
service personnel. The brewer should be unplugged
when servicing, except when electrical tests are re-
quired and the test procedure specifically states to
plug-in the brewer.
COMPONENT ACCESS
WARNING - Disconnect the brewer from the power
source before the removal of any panel or the replace-
ment of any component.
All components are accessible by the removal
of the top cover, front inspection panel and warmer
plate(s).
The top cover is attached with one #4-40 screw.
The front inspection panel is attached with #6-32
screws.
The warmer assembly is attached with three #4-40
screws.
Contents
Control Thermostat ..............................................15
Limit Thermostat ..................................................16
ON/OFF Switch .....................................................17
Solenoid (Inlet) ....................................................19
Start Switch (Brew) ............................................. 20
Selector Switch ................................................... 20
Tank Heater ......................................................... 21
Tank Heater Switch ............................................. 22
Timer .................................................................. 24
Warmer Element ................................................. 27
Wiring Diagrams .................................... 28 thru 32
MODEL C
P1152
10841 020503
MODEL SINGLE CW
FIG. 1 COMPONENT ACCESS
Comments to this Manuals