TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualied service person-
nel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing ttings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This brewer is heated at all times. Keep away from combustibles.
WARNING Exercise extreme caution when servicing electrical equipment.
Unplug the brewer when servicing, except when electrical tests are specied.
Follow recommended service procedures
Replace all protective shields or safety notices
PROBLEM
Brew cycle will not start (CT,
CTF, CWT, CWTA, CWTB, CWTF,
CWTFA, CWTFB, SINGLE CW &
SINGLE CWF)
PROBABLE CAUSE
1. No water
2. No power or incorrect voltage
to the brewer
REMEDY
Water lines and valves to the
brewer must be open.
(A1) Check the terminal block for
120 volts across the black and
white terminals on two wire 120
volt brewers.
(A2) Check the terminal block
for 120 volts across the red and
white terminals and the black
and white terminals on three wire
120/240 volt brewers.
(A3) Check the terminal block for
200 volts on "B Series" brewers
or 230 volts on "A Series" brew-
ers across the red and black
terminals.
(B) Check circuit breakers or
fuses.
10841 020503