Bunn CWT Service Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Page 15
SERVICE (cont.)
CONTROL THERMOSTAT
MODEL CWT
MODEL SINGLE CW
Location:
The control thermostat is located inside the trunk
on the left side of the component bracket.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Locate the blue wire on the control thermostat.
3. Check the voltage across the blue wire on the
control thermostat and the white insert on
two pole 120 volt terminal block or three pole
120/240 volt terminal blocks and the red insert
on two wire 200 volt or 240 volt terminal block
with a voltmeter. Connect the brewer to the power
source. The indication must be:
a) 120 volts ac for two wire 120 volt models and
three wire 120/240 volt models.
b) 200 to 230 volts ac for two wire 200 volt or
230 volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wiring
diagrams and check the brewer wiring harness.
5. Locate the black wire on the control thermo-
stat.
6. Gently remove the capillary bulb and grommet
from the tank.
7. Check the voltage across the black wire of the
control thermostat and the white insert on the two
pole 120 volt or three pole 120/240 volt terminal
block and the red insert on the two pole 200 volt
or 230 volt terminal block with a voltmeter when
the control thermostat is turned fully clockwise.
Connect the brewer to the power source. The
indication must be:
a) 120 volts ac for two wire 120 volt models and
three wire 120/240 volt models.
b) 200 to 230 volts ac for two wire 200 volt or
230 volt models.
8. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the capil-
lary tube into the tank to the line 4.5" (6.0" for Single
CW models) above the bulb, the control thermostat
is operating properly.
If voltage is not present as described, replace the
thermostat.
Removal and Replacement:
1. Remove wires from control thermostat leads.
2. Remove the thermostat capillary bulb by firmly
pulling-up on the capillary at the tank lid. This
will disengage the grommet from the tank lid.
3. Remove the one #8-32 screw securing the con-
trol thermostat to the component bracket in the
trunk.
MODEL C
P1153
10841 071000
FIG. 2 THERMOSTAT LOCATION
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 31 32

Comments to this Manuals

No comments