BYPASS OZ/M: XX.X
(-) DONE (+)
Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads SET
NEW RECIPES. Release the ®. Press and release
the ® pad until the display reads BYPASS OZ/M.
The number represents what the brewer thinks
is the flow rate of the bypass valve in ounces per
minute.
2. If the actual flow rate of the bypass valve is known,
but is different than the number on the display, use
the (-) and (+) pads to enter the correct flow rate
in ounces per minute.
3. When finished, press and release the DONE pad.
This saves the new setting and advances to the
next function screen, CALIBRATE FLOW. Another
alternative is to press and release either of the
pads located on the front switch panel to exit the
BYPASS OZ/M function and return to the MAIN
SCREEN.
P2306
29877 022509
XXX REFILL XXX
(-) DONE (+)
SPRAY OZ/M: XX.X
(-) DONE (+)
Procedure to set the sensitivity threshold of the
refill circuit:
NOTE: Make sure the water in the tank is touching
the refill probe.
1. Press and hold the ® until the display reads SET
NEW RECIPES. Release the ®. Press and release
the ® pad until the display reads REFILL and shows
a number on both sides of the word.
2. To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right
is larger than the number on the left when water is in
contact with the refill probe in the tank.
3. When finished, press and release DONE. This saves
the new setting and advances to the next function
screen, SPRAY OZ/M. Another alternative is to
press and release either of the
pads located
on the front switch panel to exit REFILL and return
to the MAIN SCREEN.
SPRAY OZ/M
This function allows the operator to view or to enter
the actual flow rate coming out of the sprayhead. This
is NOT used to change the actual flow rate, but to tell
the internal controller how fast the water is flowing.
The unit of measure is ounces per minute (Oz/M).
Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads
P2304
P2305
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
REFILL - Range: 20 to 230
This function allows the operator to adjust the
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting
the sensitivity of the refill circuit, this will allow the
brewer to operate under various water conditions.
SET NEW RECIPES. Release the ®. Press and
release the ® pad until the display reads SPRAY
OZ/M. The number represents what the brewer
thinks is the flow rate of the sprayhead in ounces
per minute.
2. If the actual flow rate of the sprayhead is known,
but is different than the number on the display,
use the (-) and (+) pads to enter the correct flow
rate in ounces per minute.
3. When finished, press and release DONE. This saves
the new setting and advances to the next function
screen, BYPASS OZ/M. Another alternative is to
press and release either of the
pads located
on the switch panel to exit SPRAY OZ/M function
and return to the MAIN SCREEN.
BYPASS OZ/M
This function allows the operator to view or to enter
the actual flow rate coming out of the bypass nozzle.
This is NOT used to change the actual flow rate, but to
tell the internal controller how fast the water is flowing.
The unit of measure is ounces per minute.