Bunn dual sh dbc Specifications Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
Page 36
FACTORY DEFAULTS
This function allows the operator to erase all of the
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
EXIT
EXIT
REPLACE
WILL REPLACE ALL
BREW SETTINGS
ARE YOU SURE?
NO YES
FACTORY DEFAULTS
NO YES
Procedure to set factory defaults:
1. Press and hold the ® pad until SET NEW RECIPES
appears. Release the ® pad. Press and release ®
until the display reads FACTORY DEFAULTS.
2. Pressing NO in this screen will revert to the MAIN
SCREEN. Press YES to replace the defaults. This
advances to WILL REPLACE ALL BREWING SET-
TINGS. This screen will alternate with ARE YOU
SURE?.
3. Pressing NO in the confirmation screen will revert
to MAIN SCREEN, without resetting the brewing
setups to the defaults. Press YES to load the de-
faults. This will then revert to the MAIN SCREEN,
and the factory default values will replace all
previously entered values. It will NOT reset the
summation Brew counter.
P2312
29877 022509
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
FACTORY DEFAULT VALUES
Brew Lockout YES
BREW VOLUMES:
Small Batch 64 oz.
Medium Batch 128 oz.
Large Batch 192 oz.
BYPASS PERCENTAGE:
Small Batch 0%
Medium Batch 20%
Large Batch 20%
PULSE BREW TIMES:
Small Batch 40 (1st on) - 10 (off) - 5 (last on)
Medium Batch OFF
Large Batch OFF
PREINFUSION TIMES:
Small Batch OFF
Medium Batch OFF
Large Batch OFF
DRIP OUT TIMES:
Small Batch 1:00
Medium Batch 1:30
Large Batch 2:00
ENABLE ADS YES
BREW TEMPERATURE 200˚F (93˚C)
READY TEMPERATURE 195˚F (91˚C)
REFILL 155
SPRAY (OZ/MINUTE) 39.2
BYPASS (OZ/MINUTE) 24.1
FUNNEL DETECT YES
SERVER DETECT YES
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 48 49

Comments to this Manuals

No comments