MODELS W/OUT FAUCET
Models CT, CWT, CTF, CWTF, SINGLE CW & SINGLE CWF
1. Flush the water line and securely attach it to the flare fitting on the strainer or tee.
2. Turn on the water supply.
3. On CTF, CWTF and SINGLE CWF Models, place an empty vessel beneath the faucet and lift the handle until
water is dispensed.
PLUMBING REQUIREMENTS
Model C:
This model is completely portable and requires no attached plumbing.
Models CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA & CWTFB, SINGLE CW & SINGLE CWF
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi
(138 to 620kPa) from a
1
2" or larger supply line. A shut-off valve should be installed in the line before the brewer.
Install a regulator in the line when pressure is greater than 90 psi (620kPa)to reduce it to 50 psi (345kPa). The
water inlet fitting is
1
4" flare.
NOTE - Bunn-O-Matic recommends
1
4" copper tubing for installations of less than 25 feet and
3
8" for more than 25
feet from the
1
2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer
to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The
size and shape of the hole made in the supply line by this type of device may restrict water flow.
MODELS W/FAUCET
10841 101008
This equipment must be installed to comply with the International Plumbing Code of the
International Code Council and the Food Code Manual of the Food and Drug Administration
(FDA). For models installed outside the U.S.A., you must comply with the applicable
Plumbing/Sanitation Code for your area.