Page 22
SERVICE (cont.)
TANK HEATER (Cont.)
TANK HEATER SWITCH
Location:
The tank heater switch is located on the rear
of the brewer on the upper left side of the trunk.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Disconnect the black wire from the limit thermo-
stat.
3. With the tank heater switch in the "ON" position
check the voltage between the black wire removed
from the limit thermostat and the white wire or red
wire on the tank heater with a voltmeter. Connect
the brewer to the power source. The indication
must be:
a) 120V volts ac on two wire 120 volt models.
b) 240 volts ac on three wire 120/240 volt mod-
els.
c) 200 to 230 volts ac on 200 volt or 230 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the Wiring
Diagrams and check the brewer wiring harness.
P1153
10841 020503
P1168
WHI to Terminal Block
(White Insert on 120V
Two Wire Models)
RED to Terminal Block
(Red Insert on 120/240V
Threee wire Models or
200V and 230V Two
Wire Models)
BLK to Control Ther-
mostat (Brewers W/Out
Faucet) Thermal Cut-Off
to BLK from Control
Thermostat (Brewers
W/Faucet
14. Install sprayhead.
15. Reconnect the wires to the limit thermostat,
tank heater and control thermostat. See limit
thermostat and control thermostat sections in
this manual when reconnecting wires.
16. Install fill basin, secure with tank inlet fitting and
gasket. Insert water supply line through grommet
in fill basin.
17. Refer to the illustration below when reconnecting
the tank heater wires.
FIG. 16 TANK HEATER WIRING
FIG. 17 TANK HEATER SWITCH LOCATION