PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
% BYPASS
This function allows adjustment of the amount of
water that bypasses the grounds. The number signi-
fies the percentage of the brew volume which does
not flow over the coffee grounds.
Modifying recipes - bypass percentages:
Range: 0% to 90% for all three batch sizes
NOTE: If the brewer is already in the % BYPASS screen,
it is not necessary to follow steps 1 through 6 in this
section, but proceed directly to step 7.
1. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Press the
® until the display reads REVIEW RECIPES.
2. Press YES to proceed. The display should now
read NO-NAME LEFT, along with MODIFY, SHOW
and NEXT.
3. Press and release NEXT to advance to the desired
coffee name to be modified.
REVIEW RECIPES?
NO YES
3 BATCHES DONE?
NO YES
3 BATCHES DONE?
NO YES
SET PULSE BREW?
NO YES
BREW OZ. XX.X
(-) DONE (+)
% BYPASS XX.X
(-) DONE (+)
NO-NAME LEFT
MODIFYSHOWNEXT
(COFFEE NAME)
MODIFYSHOWNEXT
THAT WAS THE
LAST RECIPE
EXIT TO
NEXT FUNCTION
SCREEN
ADVANCES TO ALL OTHER
COFFEE NAMES PROGRAMMED
IN THE BREWER'S MEMORY
WHEN THE LAST COFFEE NAME
IN THE BREWER'S MEMORY IS
DISPLAYED, PRESSING NEXT
WILL EXIT AND THE DISPLAY
WILL THEN READ:
SEE MODIFYING
PULSE BREW ON
THE FOLLOWING PAGE
OR PRESS AND RELEASE
EITHER ON/OFF SWITCH TO
EXIT THE % BYPASS SETUP
AND RETURN TO THE MAIN
SCREEN
P2292
4. Press and release MODIFY. The display should
read BREW OZ.
5. Press and release DONE. The display should read
3 BATCHES DONE?.
6. Press and release YES. The display should now
read % BYPASS, and a batch light will be blinking.
Press and release the batch size to be modified.
7. Using (-) and (+) set the amount of bypass water
(percentage) to be dispensed around the grounds
for that particular batch size.
8. When finished, press another batch size and repeat
step #7 for each batch to be modified.
9. When finished setting all batch sizes, press DONE.
The display should read 3 BATCHES DONE?
10. If they are not correct, press and release NO to
return to the % BYPASS setup screen.
11. If the 3 batch sizes are correct, press YES. This will
advance to SET PULSE BREW. Another alternative
is to press either of the
pads to exit the %
BYPASS setup and return to the MAIN SCREEN.